** EFFICIENCY = 42.7% ** CERTIFIED TEST REPORT NO. 2460FR DATE:, FEB 19, 2004
SC = .7 COMPUTED BY LSI PROGRAM **TEST-LITE**
Calculite
®
HID Downlight C9E28VN
Page 2 of 2 9" Aperture, ED28 (Enclosed), Metal Halide, Narrow Beam
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Job Information Type:
4,500
2,250
6,750
9,000
6,000
12,000
30°
60°
30°
60°
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .57 .57 .57 .57 .56 .56 .53 .53 .51 .51 .48
1 .55 .54 .53 .52 .53 .51 .51 .49 .49 .48 .46
2 .53 .51 .49 .48 .50 .47 .48 .46 .47 .45 .44
3 .51 .48 .46 .45 .47 .44 .46 .44 .45 .43 .42
4 .49 .46 .44 .42 .45 .42 .44 .41 .43 .41 .40
5 .47 .43 .41 .39 .43 .39 .42 .39 .41 .38 .37
6 .45 .41 .39 .37 .41 .37 .40 .37 .40 .36 .36
7 .43 .39 .37 .35 .39 .35 .38 .35 .38 .34 .34
8 .41 .37 .35 .33 .37 .33 .36 .33 .36 .32 .32
9 .39 .35 .33 .31 .35 .31 .34 .31 .34 .31 .30
10 .37 .33 .31 .29 .33 .29 .33 .29 .32 .29 .28
LUMINAIRE INPUT WATTS = 205
ANGLE MEAN CP LUMENS
0 9482
5 8632 809
10 7160
15 6075 1726
20 5041
25 3948 1829
30 2866
35 1919 1239
40 1185
45 666 530
50 218
55 23 60
60 3
65 1 1
70 0
75 0 0
80 0
85 0 0
90 0
175W ED28, PHILIPS MH COATED LAMP, LUMEN RATING = 12900 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 23031
55 988
65 78
75 32
85 0
** EFFICIENCY = 48.0% ** CERTIFIED TEST REPORT NO. 2450FR, DATE: FEB 12, 2004
SC = .6 COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 4363 33.82 70.45
0-40 5602 43.43 90.45
0-60 6191 48 99.97
0-90 6193 48.01 100.00
40-90 591 4.58 9.55
60-90 1 0.01 0.03
90-180 0 0 0
0-180 6193 48.01 100.00
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .51 .51 .51 .51 .50 .50 .47 .47 .45 .45 .43
1 .49 .48 .47 .46 .47 .45 .45 .44 .44 .43 .41
2 .47 .45 .44 .43 .44 .42 .43 .41 .42 .40 .39
3 .45 .43 .41 .40 .42 .39 .41 .39 .40 .38 .37
4 .43 .41 .39 .37 .40 .37 .39 .37 .38 .36 .35
5 .41 .39 .36 .35 .38 .35 .37 .34 .37 .34 .33
6 .40 .37 .34 .33 .36 .33 .36 .33 .35 .32 .32
7 .38 .35 .32 .31 .34 .31 .34 .31 .33 .30 .30
8 .36 .33 .31 .29 .32 .29 .32 .29 .32 .29 .28
9 .35 .31 .29 .27 .31 .27 .30 .27 .30 .27 .27
10 .33 .30 .27 .26 .29 .26 .29 .26 .29 .26 .25
LUMINAIRE INPUT WATTS = 290
ANGLE MEAN CP LUMENS
0 11750
5 11130 1042
10 9674
15 8222 2335
20 6835
25 5292 2464
30 3878
35 2612 1680
40 1598
45 900 716
50 299
55 23 77
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
250W ED28, PHILIPS MH COATED LAMP, LUMEN RATING = 19475 LMS, UNIVERSAL MAGNETIC BALLAST, CL FINISH TRIM
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 31142
55 999
65 0
75 0
85 0
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 5842 30 70.25
0-40 7522 38.63 90.46
0-60 8315 42.7 100
0-90 8315 42.7 100
40-90 793 4.07 9.54
60-90 0 0 0
90-180 0 0 0
0-180 8315 42.7 100
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
Kommentare zu diesen Handbüchern