Lightolier ISF:300 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Nein Lightolier ISF:300 herunter. Lightolier ISF:300 User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 1
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
INSTALLATION INSTRUCTIONS FOR 12V LOW VOLTAGE
AND 120V REMODELER
INSTRUCTION SHEET
07-01/Rev-03
ISF:300
A. CEILING:
1. Cut an opening as indicated above. (Fig.1)
Note: Ensure that there is nothing to obstruct the
installation in the ceiling.
B. WIRE-IN:
1. Open junction box cover. (Fig.2)
2. Insert the supply lead into the junction box with a
BX connector (not included).
3. Ground the fixture.
4. Connect the white leads (NEUTRAL) together, and
the black leads (120V) together. (Fig.3, 4 or 5)
5. Close cover. (Fig.2)
Note: Be careful not to pinch leads.
C. HOUSING:
1. Slide the power pack and the housing together into
the ceiling. Snap into place. (Fig.6)
D. RESIDENCE MOUNTING FASTENERS
1. Screw both fasteners screws. (Fig.8)
OR
303MRE MOUNTING FASTENERS:
1. Place (3) holding springs, in the T slots. Slowly
push downward using a short handle screwdriver,
until trim is flush with ceiling, solidify with screws
(3) (included), (Fig.7)
ATTENTION: Insure that the spring is placed
correctly in the T slot, nice and straight then push
down slowly. The spring does not have to be
lowered completely in the slot.
CAUTION: The housing must not be used for
temporary lighting, a protective shield is
required for the lamp.
E. TRIM:
1. Install the trim using the appropriate instruction
sheet.
F. TRANSFORMER / REPLACEMENT:
(Models 301MRE, 303MRE, 401MRE)
Note: Before performing maintenance on the
transformer, make sure that the electrical supply to
the fixture is turned off.
1. Remove the junction box cover and disconnect all
wiring connected to the transformer. (Vig.9)
2. The transformer is held by double sided tape, rotate
with screwdriver under the transformer to loosen it.
(Fig.9)
3. Complete the connections (Fig.5) following the
wiring diagram.
NOTE: WARNING RISK OF FIRE
Transformer contains fixture thermal protector. Use only
replacement transformer obtained from LIGHTOLIER.
DIA* = CEILING CUT-OUT
300MR = 3-3/4" (95mm) Dia*
400MR = 4-3/4" (121mm) Dia*
1" Max. ceiling thickness
300ES = 3-3/4" (95mm) Dia*
1" Max. ceiling thickness
301MRE = 3-3/4" (95mm) Dia*
401MR = 4-3/4" (121mm) Dia*
1" Max. ceiling thickness
303MRE = 3-3/4" (95mm) Dia*
1/2" Max. ceiling thickness
SUPPLY
LEAD
FIG.1
FIG.2
JUNCTION
BOX
BX
CONNECTOR
JUNCTION
BOX
FIG.3
(MR)
INPUT (120V)
NEUTRAL (white)
GROUND
LAMP
LOW VOLTAGE
TRANSFORMER
WHITE
BLACK
THERMAL
PROTECTOR
JUNCTION
BOX
THERMAL
PROTECTOR
LAMP
FIG.4
(ES)
INPUT (120V)
GROUND
NEUTRAL (white)
BLACK
NEUTRAL
WHITE
WHITE
BLUE
FIG.5
(MRE)
FIG.7
SCREWS
FASTENERS
SCREW
"T"
SLOTS
RETAINING
SPRINGS
HOUSING
FIG.8
CEILING
COVER
FIG.6
POWER PACK
HOUSING
300MR / 400MR 300ES 301MRE - 401MRE 303MRE
JUNCTION BOX
LAMP
LOW VOLTAGE
TRANSFORMER
THERMAL
PROTECTOR
NEUTRAL (white)
GROUND
BLUE
BLACK
BLACK
INPUT (120V)
NEUTRAL (white)
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with National Electrical Code or Canadian Electrical
Code (as applicable) and local regulations. To ensure full compliance with local codes and regulations, check with your local
electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
FIG.9
SCREWDRIVER
JUNCTION BOX
Seitenansicht 0
1

Inhaltsverzeichnis

Seite 1 - INSTRUCTION SHEET

INSTALLATION INSTRUCTIONS FOR 12V LOW VOLTAGEAND 120V REMODELERINSTRUCTION SHEET07-01/Rev-03ISF:300A. CEILING:1. Cut an opening as indicat

Kommentare zu diesen Handbüchern

Keine Kommentare